That’s right, the electrical outlet we all know&nbsp;
and put up with here in North America

00:00:05.031 --> 00:00:07.880
is usually installed upside-down.

00:00:07.880 --> 00:00:12.182
Some of you might be making&nbsp;a face very similar to these right now,

00:00:12.182 --> 00:00:16.866
but the fact is this common orientation
is starting to get&nbsp;some pushback.

00:00:16.866 --> 00:00:20.252
Take a look at the packaging of new receptacles in the store.

00:00:20.252 --> 00:00:25.640
They nearly all show&nbsp;the outlet with the ground connection on top of live and neutral.

00:00:25.640 --> 00:00:30.060
The markings on the receptacles&nbsp;themselves
also imply that this should be the top.

00:00:30.720 --> 00:00:36.262
In fact for a while now there has been something&nbsp;of a…
pressure campaign, I guess you would say,&nbsp;&nbsp;

00:00:36.262 --> 00:00:40.351
to retcon what’s normal and make you&nbsp;question reality.

00:00:40.351 --> 00:00:46.380
This manufacturer has clearly obliged - they even take care to package&nbsp;them
with the ground connection at the top.

00:00:47.280 --> 00:00:53.340
The practice of treating the ground pin as the top&nbsp;
of the receptacle supposedly began in hospitals.

00:00:53.340 --> 00:00:54.659
Why?

00:00:54.659 --> 00:00:58.448
Well, the common “face” orientation we&nbsp;typically find

00:00:58.448 --> 00:01:04.436
is actually somewhat dangerous thanks to the many design flaws
of the NEMA&nbsp;receptacle and plug.

00:01:04.436 --> 00:01:11.099
Inverting the outlet certainly doesn’t fix those flaws,
but it does&nbsp;reduce the risk of some possible calamities.

00:01:11.099 --> 00:01:14.878
So you will sometimes hear that this is technically&nbsp;incorrect,

00:01:14.878 --> 00:01:20.003
and that installing the outlet with the ground pins up is the proper way to do it.

00:01:21.441 --> 00:01:23.964
There’s&nbsp;just one small problem, here:

00:01:23.964 --> 00:01:26.042
nobody cares!

00:01:26.042 --> 00:01:27.652
I don’t care.

00:01:27.652 --> 00:01:29.911
Most electricians don’t seem to&nbsp;care.

00:01:29.911 --> 00:01:35.526
And I honestly think you don’t need to or in fact should care.

00:01:35.526 --> 00:01:38.022
That’s right, this&nbsp;is a debunk.

00:01:38.022 --> 00:01:43.931
While there is some truth to the idea that the ground-down orientation is&nbsp;not ideal,

00:01:43.931 --> 00:01:46.033
and don’t worry I’ll show you why,

00:01:46.033 --> 00:01:51.803
there are many confounding issues here which make&nbsp;advocating for its inverse,

00:01:51.803 --> 00:01:56.170
to put it mildly, pedantic and/or paranoid.

00:01:56.170 --> 00:01:58.321
At least, in my&nbsp;opinion.

00:01:58.321 --> 00:02:03.364
If you suddenly woke up and found someone had turned all your outlets around
in the&nbsp;middle of the night,

00:02:03.364 --> 00:02:06.730
it would be irrelevant the vast majority of the time,

00:02:06.730 --> 00:02:12.403
maybe very slightly safer in&nbsp;a few extremely specific scenarios,

00:02:12.403 --> 00:02:19.200
and the rest of the time it would be supremely irritating&nbsp;and,
in fact, introduce some new risks of its own.

00:02:19.860 --> 00:02:24.504
The first order of business we have on&nbsp;the agenda today is rules.

00:02:24.504 --> 00:02:27.730
Because there actually aren’t any about this.

00:02:27.730 --> 00:02:34.860
Peruse&nbsp;the National Electric Code all you want and you won’t find a specific rule
for how&nbsp;this receptacle type should be oriented.&nbsp;&nbsp;

00:02:35.520 --> 00:02:42.702
There are plenty of rules regarding spacing along&nbsp;
walls and what kind of outlet can be used in what&nbsp;circumstances

00:02:42.702 --> 00:02:45.864
but as far as how you wanna install&nbsp;this guy in the wall?

00:02:45.864 --> 00:02:47.544
Totally up to you.

00:02:47.544 --> 00:02:52.602
It’s so up to you that here in Chicagoland we like to&nbsp;install them sideways.

00:02:52.602 --> 00:02:58.921
Nearly every home I’ve ever been in around here
has ‘em installed just like&nbsp;this.

00:02:58.921 --> 00:03:01.380
And you’re right, the hot blade is on top!

00:03:02.280 --> 00:03:04.788
I’m not entirely sure why this is common here

00:03:04.788 --> 00:03:11.005
but&nbsp;it probably has something to do with the fact that all electrical work
has to be done in conduit&nbsp;until you get pretty far away from the city,&nbsp;&nbsp;

00:03:11.005 --> 00:03:16.995
so we don't get to just nail plastic wall boxes to&nbsp;studs
and run Romex around the place like&nbsp;the rest of you can

00:03:16.995 --> 00:03:20.580
and for some reason this&nbsp;orientation sticks around like deep dish pizza.

00:03:21.120 --> 00:03:22.924
Anyway, that’s not important.

00:03:22.924 --> 00:03:27.740
What is important&nbsp;is that there isn’t a definite right or wrong here.

00:03:27.740 --> 00:03:31.360
And, on a gut level, you probably already knew&nbsp;that.

00:03:31.360 --> 00:03:35.089
Just look at the test and reset buttons on a GFCI outlet.

00:03:35.089 --> 00:03:41.876
These words aren’t printed both&nbsp;ways just for grins and giggles,
 the manufacturer knows it could be installed either —

00:03:41.876 --> 00:03:44.497
or indeed&nbsp;neither — way.

00:03:44.497 --> 00:03:48.335
And in case that’s not convincing, take a look at this fancy thing I found.

00:03:48.335 --> 00:03:52.143
This&nbsp;duplex receptacle features both orientations!

00:03:52.143 --> 00:03:54.510
Good luck picking just one.

00:03:54.510 --> 00:03:55.584
So.

00:03:55.584 --> 00:03:58.323
What’s&nbsp;the deal with the whole discourse, then?

00:03:58.323 --> 00:04:01.417
Why do some folks insist that we&nbsp;should turn this…

00:04:01.417 --> 00:04:03.720
frown upside-down?

00:04:04.500 --> 00:04:06.620
Well, there are two main reasons.

00:04:06.620 --> 00:04:13.095
Both of which&nbsp;ultimately stem from the fact that
the design of this plug and its receptacle is bad.

00:04:13.095 --> 00:04:18.827
The blades&nbsp;aren’t sleeved with any insulating material,
and when the plug is partially inserted

00:04:18.827 --> 00:04:23.372
it becomes live despite the conductive blades remaining ever-so-touchable.

00:04:23.372 --> 00:04:26.580
Especially&nbsp;when you have small fingers like a child does.

00:04:27.780 --> 00:04:29.126
It’s not great.

00:04:29.126 --> 00:04:32.710
But! If the outlet were simply&nbsp;rotated 180 degrees,

00:04:32.710 --> 00:04:38.700
the risk of accidentally touching the live blade
as you insert or&nbsp;remove the plug becomes muchly mitigated!

00:04:39.240 --> 00:04:43.740
See, now the ground pin is on top, so it’s&nbsp;a lot harder to get your thumb in there.

00:04:44.460 --> 00:04:47.091
Except… well, two things.

00:04:47.091 --> 00:04:52.746
One, when I hold onto&nbsp;a plug
I’ve usually got my index finger curled around the bottom.

00:04:52.746 --> 00:04:55.974
So if I were plugging something&nbsp;into an outlet like this,

00:04:55.974 --> 00:05:00.806
my thumb might be a bit safer but I could still get zapped down below.

00:05:00.806 --> 00:05:02.704
But&nbsp;perhaps more importantly —

00:05:02.704 --> 00:05:06.494
not all plugs even have a ground pin, do they?

00:05:06.494 --> 00:05:09.862
For this plug it doesn’t&nbsp;make a lick of difference where the ground pin is

00:05:09.862 --> 00:05:11.822
because it’s not there!

00:05:11.822 --> 00:05:19.090
So I don’t really buy&nbsp;reducing shock risk from simply handling the plug
as a reason to invert the receptacle.

00:05:19.090 --> 00:05:23.625
It’s not&nbsp;the most commonly cited reason to avoid the “face” orientation,

00:05:23.625 --> 00:05:30.519
and in fact I’m having a hard time&nbsp;tracking down a solid source of that case being made but I swear I’ve run across it before

00:05:30.519 --> 00:05:32.843
and&nbsp;besides it’s a good lead-in to this side note:

00:05:32.843 --> 00:05:41.677
Side-note, there is a weird difference between&nbsp;three-prong plugs and two-prong plugs that I hadn’t really given any thought about until it&nbsp;was pointed out to me.

00:05:41.677 --> 00:05:45.460
If you ever come across something with a very old power cord,

00:05:45.460 --> 00:05:50.849
you’ll find&nbsp;that our plugs used to be much worse and outright terrifying.

00:05:50.849 --> 00:05:52.975
Look at the plug on this old tape&nbsp;recorder.

00:05:52.975 --> 00:05:59.865
There’s hardly any clearance between the metal blades and the plastic body,
and there&nbsp;isn’t much of a grip to grab hold of, either.

00:05:59.865 --> 00:06:03.035
And I’ve actually seen some even worse than this.

00:06:03.035 --> 00:06:07.527
Over&nbsp;the years we made the two-prong plug at least a little bit safer

00:06:07.527 --> 00:06:13.666
by flaring the plastic body out&nbsp;towards the end
and adding this lip for even more clearance.

00:06:13.666 --> 00:06:19.500
But… grounded plugs largely haven’t&nbsp;
gotten that particular memo for some reason.

00:06:20.340 --> 00:06:27.245
This power supply cord has its plug blades&nbsp;
barely any further from the edge than the 50&nbsp;year old tape recorder.

00:06:27.245 --> 00:06:30.770
And… that’s all kinds&nbsp;of weird!

00:06:30.770 --> 00:06:36.652
It has gotten a little better - 
this power strip's plug has a bit more meat around the blades.

00:06:36.652 --> 00:06:40.364
But it's still not quite as much as a standard two-pronger.

00:06:40.364 --> 00:06:43.983
I suppose maybe&nbsp;this makes them fit better into power strips

00:06:43.983 --> 00:06:50.334
(or maybe some other application would be messed&nbsp;up if the plug shape were modified to be closer to the two-pronged plug).

00:06:50.334 --> 00:06:53.462
Whatever the reason, it&nbsp;means that, ironically,

00:06:53.462 --> 00:06:58.753
cords meant to introduce an element of safety
by way of grounding&nbsp;the appliance they’re connected to

00:06:58.753 --> 00:07:03.300
often make the process of plugging and unplugging&nbsp;
that appliance just a little bit spicier.

00:07:04.020 --> 00:07:10.543
However, holding the plug wrong and getting&nbsp;a nice little shock from it
isn’t the only&nbsp;problem we face.

00:07:10.543 --> 00:07:16.032
There’s also the issue of&nbsp;partially-inserted plugs and foreign objects.

00:07:16.032 --> 00:07:22.839
Again, this plug is bad, and even if nobody’s had&nbsp;
a shocking time of it and it’s inserted perfectly well,

00:07:22.839 --> 00:07:26.151
it can nevertheless become slightly&nbsp;dislodged.

00:07:26.151 --> 00:07:32.188
This plug is still reaching far enough in to make contact
with the live conductors&nbsp;in the receptacle,

00:07:32.188 --> 00:07:35.745
but look at all that room we have for things to sneak in there.

00:07:35.745 --> 00:07:37.344
Things&nbsp;like keys,

00:07:37.344 --> 00:07:38.589
or coins,

00:07:38.589 --> 00:07:40.038
or scissors,

00:07:40.038 --> 00:07:41.280
or knives.

00:07:42.000 --> 00:07:44.719
[metal clanging]
Do you have any idea how many games of

00:07:44.719 --> 00:07:49.146
“throw the knives at the wall” have been ruined
thanks to these terrible plugs?

00:07:49.146 --> 00:07:50.844
It’s at least one.

00:07:50.844 --> 00:07:54.665
If a flat metal object manages to slip into this little crack,

00:07:54.665 --> 00:07:56.667
it can bridge those pins and&nbsp;poof!

00:07:56.667 --> 00:07:57.256
[poof]

00:07:57.256 --> 00:08:01.059
You’ve tripped a circuit breaker and made a nasty char mark on the wall.

00:08:01.059 --> 00:08:04.098
Or possibly,&nbsp;if things go terribly wrong,

00:08:04.098 --> 00:08:04.860
started a fire.

00:08:05.640 --> 00:08:10.067
Of course, outside of Boston, most&nbsp;people don’t play 
“throw the knives&nbsp;at the wall.”

00:08:10.067 --> 00:08:12.120
But that doesn’t mean&nbsp;there’s no risk for the rest of us!

00:08:12.780 --> 00:08:15.577
Remember when I said this plug&nbsp;design is bad?

00:08:15.577 --> 00:08:17.550
Yeah, me too, but also -

00:08:17.550 --> 00:08:20.727
the wall plate design is bad.

00:08:20.727 --> 00:08:25.123
There are a few variations but the most basic wall plate for a duplex receptacle

00:08:25.123 --> 00:08:28.800
is held&nbsp;on with a single screw which attaches right here.

00:08:29.640 --> 00:08:34.375
Wall plates are usually plastic these days, but&nbsp;they haven’t always been.

00:08:34.375 --> 00:08:39.250
Metal wall plates used to be quite common,
and they’re still used from&nbsp;time to time today.

00:08:39.250 --> 00:08:44.744
If the single screw holding it on backs out with time or in some other way&nbsp;fails,

00:08:44.744 --> 00:08:51.473
the wall plate could fall onto the live and neutral pin
of a partially dislodged&nbsp;plug and short it out.

00:08:51.473 --> 00:08:53.040
Again, not good.

00:08:53.820 --> 00:08:57.187
But the risk of a short circuit isn’t the&nbsp;only problem.

00:08:57.187 --> 00:09:02.650
Imagine you’re working on some sort of home improvement project
and you whip out one of these bad boys.&nbsp;&nbsp;

00:09:03.120 --> 00:09:06.564
Now imagine you’re taking a measurement of the&nbsp;length of a wall,

00:09:06.564 --> 00:09:11.338
and you’ve got a boombox or something plugged into an outlet 
on that wall&nbsp;you’re measuring.

00:09:11.338 --> 00:09:15.949
You bumped the cord a little while back
and didn’t see that the plug became dislodged,

00:09:15.949 --> 00:09:18.090
and as you cast your tape to the wind -

00:09:18.090 --> 00:09:20.728
a tape that is metal, mind you.

00:09:20.728 --> 00:09:25.852
And droopy - it slips&nbsp;in that crack and lands on the live pin.

00:09:25.852 --> 00:09:26.643
Ouch.

00:09:27.000 --> 00:09:30.343
Or, let’s say you’ve decided to lean like, I&nbsp;dunno,

00:09:30.343 --> 00:09:35.254
a file or a square or a yardstick or something up against the wall next to an outlet.

00:09:35.254 --> 00:09:38.418
If it, too,&nbsp;suffers from partial dislodgement syndrome,

00:09:38.418 --> 00:09:43.020
that yardstick could fall onto the&nbsp;live pin and become live itself.

00:09:43.680 --> 00:09:47.197
Say a prayer for the person who reaches to pick it&nbsp;up next.

00:09:47.197 --> 00:09:52.011
If only the receptacle had been rotated 180 degrees!

00:09:52.011 --> 00:09:58.551
Then the ground pin would be at&nbsp;the top and even a loose plug would be less likely to start a fire or hurt someone

00:09:58.551 --> 00:10:01.200
in these&nbsp;extremely specific scenarios I’ve just described.

00:10:01.800 --> 00:10:04.739
Actually, when the ground pin is up top,

00:10:04.739 --> 00:10:08.505
the plug&nbsp;is less likely to become dislodged in the first place!

00:10:08.505 --> 00:10:12.240
The ground pin is longer and reaches deeper&nbsp;into the receptacle

00:10:12.240 --> 00:10:19.140
in order to ensure it’s the first to make contact upon plug insertion&nbsp;
and the last to break contact on removal.

00:10:19.800 --> 00:10:22.457
That makes it something of a pivot point.

00:10:22.457 --> 00:10:29.832
If&nbsp;it’s on the bottom, then a downward force on the plug will easily pull
the shorter live and&nbsp;neutral pins out somewhat.

00:10:29.832 --> 00:10:34.179
But if it’s on the top, it takes more force to get it to budge.

00:10:34.179 --> 00:10:40.012
Plus, once it does budge, the other two pins are jammed
right up against the receptacle&nbsp;face.

00:10:40.012 --> 00:10:42.120
Thus they remain mostly untouchable.

00:10:43.080 --> 00:10:47.681
Seems like we have a pretty solid reason to&nbsp;install these ground-up, right?

00:10:47.681 --> 00:10:51.368
I’d probably never trip a breaker when playing 
"throw the&nbsp;knives at the wall,"

00:10:51.368 --> 00:10:56.472
a falling metal wall plate would simply land on the ground pin so no harm no&nbsp;foul.

00:10:56.472 --> 00:11:03.229
And measuring walls with a tape measure and even leaning long flat metal objects against them&nbsp;become safer activities, too!

00:11:03.229 --> 00:11:04.260
What’s not to like?

00:11:05.400 --> 00:11:07.920
Well, you probably know what I’m gonna say next.&nbsp;&nbsp;

00:11:08.520 --> 00:11:12.041
Not all plugs have a ground prong, Harold.

00:11:12.041 --> 00:11:18.609
This&nbsp;One Weird Trick will do absolutely nothing for
ANY of these scenarios we’ve gone through

00:11:18.609 --> 00:11:22.672
if the&nbsp;loose plug in question was one of these fellas.

00:11:22.672 --> 00:11:24.606
And that’s a lot of plugs!

00:11:24.606 --> 00:11:28.440
The majority in my&nbsp;life have only two prongs and I doubt I’m alone.

00:11:29.160 --> 00:11:30.670
“Aha!” you say

00:11:30.670 --> 00:11:35.363
“but why would you be against&nbsp;reducing the risk
in the circumstances in which it could be reduced?

00:11:35.363 --> 00:11:37.860
What exactly&nbsp;is the problem with a ground-up outlet?”

00:11:38.640 --> 00:11:40.496
I’ll tell you what the problem is:

00:11:40.496 --> 00:11:42.838
They don’t make&nbsp;very good hamburgers.

00:11:42.838 --> 00:11:46.725
But also, it’s the mere existence of these:

00:11:46.725 --> 00:11:48.660
right-angle plugs.

00:11:48.660 --> 00:11:50.162
Maybe it’s a plug-in&nbsp;timer,

00:11:50.162 --> 00:11:52.349
maybe it’s the GFCI thing on a hair drier,

00:11:52.349 --> 00:11:53.586
maybe it’s a smart plug,

00:11:53.586 --> 00:11:55.380
maybe it's the venerable Kill-A-Watt,

00:11:55.380 --> 00:11:56.478
or a nice power strip,

00:11:56.478 --> 00:11:57.876
or an appliance cord,

00:11:58.260 --> 00:12:05.911
I have yet to encounter one of these which&nbsp;doesn’t assume the ground pin 
will be below&nbsp;live and neutral

00:12:05.911 --> 00:12:11.999
(or, if it’s a polarized but&nbsp;ungrounded cord,
that the wider neutral blade will be on the left).

00:12:11.999 --> 00:12:15.047
Unless it’s fancy enough&nbsp;to have one of those swiveling plugs,

00:12:15.047 --> 00:12:21.900
the cord would point straight up when inserted into an&nbsp;
outlet with the supposedly superior orientation.

00:12:22.920 --> 00:12:27.064
This reason alone is enough to get me to say

00:12:27.064 --> 00:12:28.076
“nahhh”

00:12:28.076 --> 00:12:30.586
to the idea of flipping the outlet around.

00:12:30.586 --> 00:12:36.637
There are just far too many products out there
which&nbsp;would become absolutely horrid to use.

00:12:36.637 --> 00:12:39.893
And not just from aesthetics, but from function&nbsp;as well!

00:12:39.893 --> 00:12:46.260
Cable management is a lot harder when the cord just wants to flail about -&nbsp;
and then this becomes a tripping hazard!

00:12:46.800 --> 00:12:54.545
Unless and until devices start getting shipped&nbsp;with right angle plugs
that support the ground-up&nbsp;receptacle orientation,

00:12:54.545 --> 00:13:01.398
attempting to paint this&nbsp;as “correct” is, to me anyway, utter nonsense.

00:13:01.398 --> 00:13:04.157
Luckily for us and our sideways outlets,

00:13:04.157 --> 00:13:06.465
right-angle plugs&nbsp;work no matter what!

00:13:06.465 --> 00:13:10.577
Here’s how my computer’s power strip
is plugged into the outlet under my&nbsp;desk.

00:13:10.577 --> 00:13:12.420
It’s a bit cheeky but it’s doin’ the trick.

00:13:13.080 --> 00:13:13.874
But wait!

00:13:13.874 --> 00:13:15.048
There’s more!

00:13:15.048 --> 00:13:20.685
Right-angle plugs greatly&nbsp;reduce the risk of a cord getting dislodged in the first place.

00:13:20.685 --> 00:13:24.554
Our plugs only get droopy like this&nbsp;for two reasons:

00:13:24.554 --> 00:13:28.587
A) the receptacle is badly worn out
and it’s not gripping the prongs well

00:13:28.587 --> 00:13:33.841
so over&nbsp;time gravity pulls down on the cord
and it pivots away from the wall and/or

00:13:33.841 --> 00:13:36.354
2) they get bumped.

00:13:36.354 --> 00:13:39.559
A right-angle plug solves both of those problems by

00:13:39.559 --> 00:13:42.416
1) being more difficult to bump into and

00:13:42.416 --> 00:13:46.064
B)&nbsp;the weight of its cord pulls straight down

00:13:46.064 --> 00:13:54.184
and thus it naturally hangs from this position without&nbsp;relying much at all
on the friction between the blades of the plug and the receptacle itself.

00:13:54.184 --> 00:14:00.803
It takes&nbsp;quite a strong downward yank on the cord just to get it to start backing out.

00:14:00.803 --> 00:14:04.740
Yet when&nbsp;the same cord is plugged into an inverted outlet,

00:14:05.640 --> 00:14:11.400
it’s trying to come out all on its own thanks&nbsp;
to all its weight pulling it away from the wall.

00:14:12.180 --> 00:14:17.467
So if you ask me, right-angle plugs which assume&nbsp;
the ground pin will be at the bottom

00:14:17.467 --> 00:14:21.709
are not only a reason to just ignore the whole upside-down&nbsp;outlet argument,

00:14:21.709 --> 00:14:29.075
but right-angle plugs themselves are also a pretty good solution
to the&nbsp;problems inverting the outlet attempts to solve!

00:14:29.839 --> 00:14:34.219
Assuming, that is, they don’t completely&nbsp;oppose the orientation of the receptacle.&nbsp;&nbsp;

00:14:35.220 --> 00:14:39.609
Honestly, it’s awfully strange how most of our&nbsp;power cords

00:14:39.609 --> 00:14:44.005
just stick straight out from the wall a bit, isn’t it?

00:14:44.005 --> 00:14:46.560
Seems like we’re just&nbsp;asking for trouble most of the time.

00:14:47.220 --> 00:14:50.850
Oh, and right-angle plugs don’t even need to be&nbsp;grounded -

00:14:50.850 --> 00:14:54.685
here’s an ungrounded extension cord with a right-angle plug.

00:14:54.685 --> 00:15:00.240
It stays flush&nbsp;with the wall so is less likely to get bumped,
and the weight of its cord&nbsp;won’t try to pull it out.&nbsp;&nbsp;

00:15:00.900 --> 00:15:05.145
And yeah, the manufacturer put the cord at a 45&nbsp;degree angle

00:15:05.145 --> 00:15:11.913
so that no matter what orientation your receptacles happen to be,
the cord is&nbsp;at least marginally well-organized.

00:15:11.913 --> 00:15:16.008
Plus it avoids issues with two of them being used&nbsp;with the same receptacle.

00:15:16.008 --> 00:15:19.016
If there’s something you should be advocating for,

00:15:19.016 --> 00:15:22.380
I would say it&nbsp;would be making the right-angle plugs the default.

00:15:23.040 --> 00:15:25.898
But maybe not this particular design.

00:15:25.898 --> 00:15:28.367
Or indeed&nbsp;several others.

00:15:28.367 --> 00:15:32.121
The main downside of right-angle plugs is that they are harder to use,

00:15:32.121 --> 00:15:34.082
especially&nbsp;to unplug.

00:15:34.082 --> 00:15:42.987
And, the slimmest among them make brushing against the prongs even more likely since&nbsp;you kind of have to dig your nails into the sides for a good grip.

00:15:43.849 --> 00:15:48.948
It’s actually quite strange&nbsp;how much of a Wild West plug design is over here.

00:15:48.948 --> 00:15:52.493
These two variants are certainly the most common&nbsp;these days,

00:15:52.493 --> 00:15:56.371
but when it comes to right-angle plugs, anything goes apparently.

00:15:56.371 --> 00:16:00.161
He’s a replacement&nbsp;lamp cord plug and its wires go out the side!

00:16:00.780 --> 00:16:04.212
So, again, if there’s something we oughta work&nbsp;on,

00:16:04.212 --> 00:16:08.372
I’d say it’s getting the plug ducks in a row first.

00:16:08.372 --> 00:16:12.480
It might also be worth looking into&nbsp;
sleeving the blades like many other countries do.

00:16:13.140 --> 00:16:19.187
Whether that can be done without breaking&nbsp;compatibility
with the installed base of&nbsp;receptacles is the real question,

00:16:19.187 --> 00:16:20.820
and&nbsp;I hope somebody’s looking into it.

00:16:21.420 --> 00:16:27.219
In the meantime, don’t get too hung up on the&nbsp;
upside down or right-side up issue.

00:16:27.219 --> 00:16:30.963
As we see around Chicago, it's not even a binary.

00:16:31.649 --> 00:16:35.741
As ever, use caution when plugging and unplugging things from the wall.

00:16:35.741 --> 00:16:39.098
And now that you’re aware&nbsp;of this issue (if you weren't already),

00:16:39.098 --> 00:16:40.560
hopefully you’ll look out for it.

00:16:41.220 --> 00:16:43.125
Although.

00:16:43.125 --> 00:16:50.956
I do just want to point out that I&nbsp;spent 15 minutes throwing knives at the wall
trying to slot one in,

00:16:50.956 --> 00:16:56.751
and although I came&nbsp;close,
in the end I had to resort to movie magic and stage the thing.

00:16:56.751 --> 00:16:58.806
Take from that what&nbsp;you will.

00:16:58.806 --> 00:17:01.924
And if for some reason you feel you still can’t trust yourself,

00:17:01.924 --> 00:17:04.089
why not pick up some&nbsp;of these?

00:17:04.708 --> 00:17:05.956
They work for children.

00:17:05.956 --> 00:17:07.534
For a while, anyway.

00:17:08.419 --> 00:17:11.513
Thanks for watching, stay safe out there,&nbsp;be reasonable,

00:17:11.513 --> 00:17:13.110
and eat your vegetables.

00:17:13.906 --> 00:17:16.545
♫ pedantically smooth jazz ♫

00:17:18.101 --> 00:17:23.729
Hey, just so you know there’s gonna be a&nbsp;Connextras follow-up to this
on tamper-resistant receptacles.

00:17:23.729 --> 00:17:31.021
They are now a code requirement for&nbsp;new construction and I thought that they largely fix many of the problems we've been talking about

00:17:31.021 --> 00:17:35.605
but I did a sanity check and revealed that,
uh, not all designs do so.

00:17:35.605 --> 00:17:38.312
Gonna talk about that&nbsp;over on the second channel if you’re interested.

00:17:40.834 --> 00:17:44.049
It would be irrelevant in the vast majority&nbsp;of the time, oh.

00:17:44.049 --> 00:17:45.389
[frustration sounds]

00:17:46.672 --> 00:17:48.772
Good job, Steve, copying that.

00:17:48.772 --> 00:17:51.600
There is a weird difference&nbsp;between three plong bleuh

00:17:52.860 --> 00:17:54.951
I knew that was gonna be hard to say.

00:17:54.951 --> 00:17:56.198
Imagine you’re working on

00:17:56.198 --> 00:17:56.698
[clears throat]

00:17:56.698 --> 00:17:58.291
blahbittybloobitybuddeh

00:17:58.291 --> 00:17:59.435
Imagine you’re working on -

00:18:00.000 --> 00:18:03.120
Say a prayer for the next person who&nbsp;
reaches to pick up the next… what?

00:18:05.040 --> 00:18:10.623
But holding the plug wrong and getting a&nbsp;
nice little shock from it isn’t the only&nbsp;problem we face.

00:18:12.725 --> 00:18:15.838
Some of them include&nbsp;a receptacle that’s not cooperating.

00:18:15.838 --> 00:18:19.008
…power strip is plugged into the outlet&nbsp;under my desk at home.

00:18:19.406 --> 00:18:20.391
It’s a beet cheek…

00:18:23.444 --> 00:18:25.347
OK, so hopefully we can put this issue to rest.

00:18:25.347 --> 00:18:31.417
Seriously, it irks me so much how apparently nobody considers right-angle plugs OR the fact that the "fix" doesn't do anything at all when two-prongers are in-use.

00:18:31.417 --> 00:18:34.653
In hindsight, the Chicago arrangement with neutral on top might be the best...

00:18:34.653 --> 00:18:37.508
But seriously, word to the wise,
deep dish is for tourists, mostly.

00:18:37.508 --> 00:18:38.841
Look up tavern style.

00:18:38.841 --> 00:18:39.718
That's the real Chicago pizza.